CAT 6 F/UTP

0 out of 5

Application Area
IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, 10GBase-T, IEEE 802.5 16 MB, ISDN, TPDDI,
ATM Power over Ethernet (PoE) / PoE+

Cable Construction

• 23 AWG Bare Copper
• PE Insulation
• Pair Seperator PE
• Polyester Band
•Tinned Copper Drain Wire
• Al-Pet Foil 100% Coverage
• Outer Sheath PVC,HFFRor PE

Standards

EIA/TIA-568-C.2
ISO/IEC 11801 2nd ed
IEC 61156-5 , EN 50173-1
EN 50288-5-1
Technical Properties

Copper Weight 20 kg/km
Min. Bending radius    during draw in 52 mm
Min. Bending radius    permanently installed 26 mm
Max. Tensile Strength 100 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -30°C … + 70°C
Packing 305 / 500 m
Electrical Properties                               at 20ºC

Max. Conductor Resistance 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance 50 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 67 %
Delay Skew 45 ns / 100 m
Min. TCL Level 2
Coupling Attenuation  Type 2
Transfer Impedance Class 2
Test Voltage 1000 V
Operating Voltage 125 V
Product Name Outer Sheath Material Euro Class Cable Weight Flame Retardancy Corrosive Gases Smoke Density Dawnlaod
Data Sheet
CAT 6 F/UTP PVC Eca 51 Kg/Km EN 60332-1-2 N/A N/A  PVC
CAT 6 F/UTP HFFR HFFR Dca 52 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2  HFFR
CAT 6 F/UTP PE PE Fca 45 Kg/Km N/A N/A N/A  PE
Frequency
(MHz)
Attenuation
(dB/100 m)
NEXT
(dB)
PS – NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 83 80 85 82 83 80 25
4 3.6 73 70 70 67 70 67 31
10 6.0 73 70 65 62 60 57 30
100 19.5 55 52 40 37 35 32 25
200 28.5 50 47 25 22 30 27 22
250 32.0 45 42 25 22 22 19 22
300 33.0 40 37 15 12 20 17 22
400 39.0 40 37 7 4 20 17 20