LIHCH-TP
Application Area
These cables are used for connections in the electronic control technology, signal and data transmission cables for voice frequency transmissions.
Thanks to the HFFR material that is used in these cables, they are flame retardant, moreover they do not extract poisonous gases and black smoke when they are in fire.
Cable Construction
Inner Conductor |
Electrolytic Twisted Copper Wire, Class 5 IEC 60228; DIN VDE 0295 |
Insulation |
HFFR, DIN 47100 Suitable for isolated color application EN 502902-2-26 |
Paires |
Cores are stranded to pairs
|
Stranding |
Twisted in group
|
Polyester |
Pet Band 100% Coverage |
Screen |
Tinned Copper Braid Wire
|
Outer sheath |
HFFR, RAL 7001 Grey EN 50290-2-27 |
Technicial Properties
Operating Temperature | -30°C … + 70°C |
Min. Bending radius | 15 x D |
Insulation Resistance | 200 MΩ x km |
Operating Voltage | |
0,22 mm² – 0,34 mm² | 250 V |
≥0,50 mm2 | 300/500 V |
Test Voltage | |
0,22 ve 0,34 mm² | 1200 V |
≥0,50 mm² | 2000 V |
Packing | 500 / 1000 m |
Standards
TSE K 353, DIN VDE 0812 |
Euro Class |
B2ca |
Flame Retardancy Test |
EN 60332-1-2 |
Smoke Density Test |
EN 61034-2 |
Corrosive Gas Test |
EN 50267-2-3 |
EMC |
Electromagnetic compatibility |
İletken Çapı (mm²) |
İletken Direnci (Ohm/km @ 20 °C) |
0.22 mm² | 96.00 Ω/km |
0.34 mm² | 56.00 Ω/km |
0.50 mm² | 39.00 Ω/km |
0.75 mm² | 26.00 Ω/km |
1.00 mm² | 19.50 Ω/km |
1.50 mm² | 13.30 Ω/km |
2.50 mm² | 7.98 Ω/km |
Damar Sayısı x Kesit (mm²) |
Kablo Çapı (mm) |
Bakır Ağırlığı (kg/km) |
Kablo Ağırlığı (kg/km) |
2 x 2 x 0.22 | 5.8 | 17.0 | 45 |
3 x 2 x 0.22 | 6.0 | 22.0 | 58 |
4 x 2 x 0.22 | 6.8 | 26.0 | 68 |
5 x 2 x 0.22 | 7.5 | 32.0 | 76 |
6 x 2 x 0.22 | 8.0 | 36.0 | 87 |
8 x 2 x 0.22 | 8.8 | 52.0 | 106 |
10 x 2 x 0.22 | 10.0 | 58.0 | 132 |
12 x 2 x 0.22 | 12.0 | 66.0 | 146 |
14 x 2 x 0.22 | 10.8 | 76.0 | 170 |
2 x 2 x 0.34 | 6.3 | 29.0 | 52 |
3 x 2 x 0.34 | 6.6 | 35.0 | 63 |
4 x 2 x 0.34 | 7.4 | 52.0 | 80 |
5 x 2 x 0.34 | 8.1 | 59.0 | 93 |
6 x 2 x 0.34 | 8.7 | 71.0 | 109 |
8 x 2 x 0.34 | 9.8 | 85.0 | 140 |
10 x 2 x 0.34 | 11.6 | 113.0 | 164 |
12 x 2 x 0.34 | 13.2 | 128.0 | 250 |
14 x 2 x 0.34 | 14.1 | 143.0 | 277 |
2 x 2 x 0.50 | 7.6 | 35.0 | 72 |
3 x 2 x 0.50 | 8.1 | 45.0 | 88 |
4 x 2 x 0.50 | 8.8 | 65.0 | 107 |
5 x 2 x 0.50 | 9.8 | 76.0 | 131 |
6 x 2 x 0.50 | 10.5 | 91.0 | 152 |
8 x 2 x 0.50 | 12.0 | 111.0 | 196 |
10 x 2 x 0.50 | 13.5 | 147.0 | 235 |
12 x 2 x 0.50 | 13.9 | 168.0 | 298 |
14 x 2 x 0.50 | 14.8 | 197.0 | 343 |
2 x 2 x 0.75 | 8.3 | 55.0 | 86 |
3 x 2 x 0.75 | 8.8 | 70.0 | 109 |
4 x 2 x 0.75 | 9.8 | 90.0 | 137 |
5 x 2 x 0.75 | 10.5 | 106.0 | 163 |
6 x 2 x 0.75 | 11.5 | 136.0 | 190 |
8 x 2 x 0.75 | 13.1 | 167.0 | 245 |
10 x 2 x 0.75 | 15.1 | 208.0 | 310 |
12 x 2 x 0.75 | 16.1 | 239.0 | 402 |
14 x 2 x 0.75 | 17.2 | 271.0 | 453 |
2 x 2 x 1.00 | 9.2 | 50.0 | 101 |
3 x 2 x 1.00 | 9.5 | 85.0 | 130 |
4 x 2 x 1.00 | 10.5 | 116.0 | 160 |
5 x 2 x 1.00 | 11.2 | 144.0 | 190 |
6 x 2 x 1.00 | 12.5 | 166.0 | 230 |
8 x 2 x 1.00 | 14.1 | 207.0 | 295 |
10 x 2 x 1.00 | 16.0 | 258.0 | 365 |
12 x 2 x 1.00 | 16.8 | 299.0 | 471 |
14 x 2 x 1.00 | 17.9 | 341.0 | 533 |
2 x 2 x 1.50 | 10.0 | 68.0 | 133 |
3 x 2 x 1.50 | 10.6 | 92.0 | 163 |
4 x 2 x 1.50 | 11.6 | 120.0 | 202 |
5 x 2 x 1.50 | 13.4 | 146.0 | 253 |
6 x 2 x 1.50 | 14.5 | 172.0 | 295 |
8 x 2 x 1.50 | 15.8 | 222.0 | 364 |
10 x 2 x 1.50 | 18.2 | 276.0 | 453 |
12 x 2 x 1.50 | 18.6 | 320.0 | 519 |
14 x 2 x 1.50 | 19.8 | 374.0 | 591 |
2 x 2 x 2.50 | 12.6 | 102.0 | 203 |
3 x 2 x 2.50 | 13.5 | 146.0 | 283 |
4 x 2 x 2.50 | 14.8 | 188.0 | 317 |
5 x 2 x 2.50 | 16.6 | 230.0 | 393 |
6 x 2 x 2.50 | 18.2 | 276.0 | 463 |
8 x 2 x 2.50 | 20.0 | 360.0 | 677 |
10 x 2 x 2.50 | 23.0 | 445.0 | 726 |
12 x 2 x 2.50 | 23.5 | 526.0 | 839 |
14 x 2 x 2.50 | 25.0 | 612.0 | 961 |
Categories: Fire Alarm Cables, HFFR Signal Control Cables, Signal Control Cables