LIYCY-TP
Application Area
These cables are used for connections in the electronic control technology, signal and data transmission cables for voice frequency transmissions.
Cable Construction
Inner Conductor |
Electrolytic Twisted Copper Wire, Class 5 IEC 60228; DIN VDE 0295 |
Insulation |
PVC, DIN 47100 Suitable for isolated color application EN 502902-2-21 TI52 |
Pairs |
Cores are stranded to pairs
|
Stranding |
Twisted in group
|
Polyester |
Pet Band 100% Coverage |
Screen |
Tinned Copper Braid Wire
|
Outer sheath |
PVC, RAL 7001 Grey EN 50290-2-22 TM52 |
Technicial Properties
Operating Temperature | -30°C … + 70°C |
Min. Bending radius | 15 x D |
Insulation Resistance | 200 MΩ x km |
Operating Voltage | |
0.22 mm² – 0.34 mm² | 250V |
≥0.50 mm2 | 300/500 V |
Test Voltage | |
0.22 ve 0.34 mm² | 1200 V |
≥0.50 mm² | 2000 V |
Packing | 500 / 1000 m |
Standards
TSE K 353, DIN VDE 0812 |
Euro Class |
Eca |
Flame Retardancy Test |
EN 60332-1-2 |
EMC |
Electromagnetic compatibility |
Conductor Cross Section (mm²) |
Conductor Resistance max. (Ohm/km @ 20 °C) |
0.22 mm² | 96.00 Ω/km |
0.34 mm² | 56.00 Ω/km |
0.50 mm² | 39.00 Ω/km |
0.75 mm² | 26.00 Ω/km |
1.00 mm² | 19.50 Ω/km |
1.50 mm² | 13.30 Ω/km |
2.50 mm² | 7.98 Ω/km |
No. Of Cores x Cross Section (mm²) |
Overall Diameter (mm) |
Copper Weight (kg/km) |
Cable Approx. Weight (kg/km) |
2 x 2 x 0.22 | 5.8 | 17.0 | 45 |
3 x 2 x 0.22 | 6.0 | 22.0 | 58 |
4 x 2 x 0.22 | 6.8 | 26.0 | 68 |
5 x 2 x 0.22 | 7.5 | 32.0 | 76 |
6 x 2 x 0.22 | 8.0 | 36.0 | 87 |
8 x 2 x 0.22 | 8.8 | 52.0 | 106 |
10 x 2 x 0.22 | 10.0 | 58.0 | 132 |
12 x 2 x 0.22 | 12.0 | 66.0 | 146 |
14 x 2 x 0.22 | 10.8 | 76.0 | 170 |
2 x 2 x 0.34 | 6.3 | 29.0 | 52 |
3 x 2 x 0.34 | 6.6 | 35.0 | 63 |
4 x 2 x 0.34 | 7.4 | 52.0 | 80. |
5 x 2 x 0.34 | 8.1 | 59.0 | 93 |
6 x 2 x 0.34 | 8.7 | 71.0 | 109 |
8 x 2 x 0.34 | 9.8 | 85.0 | 140 |
10 x 2 x 0.34 | 11.6 | 113.0 | 164 |
12 x 2 x 0.34 | 13.2 | 128.0 | 250 |
14 x 2 x 0.34 | 14.1 | 143.0 | 277 |
2 x 2 x 0.50 | 7.6 | 35.0 | 72 |
3 x 2 x 0.50 | 8.1 | 45.0 | 88 |
4 x 2 x 0.50 | 8.8 | 65.0 | 107 |
5 x 2 x 0.50 | 9.8 | 76.0 | 131 |
6 x 2 x 0.50 | 10.5 | 91.0 | 152 |
8 x 2 x 0.50 | 12 | 111.0 | 196 |
10 x 2 x 0.50 | 13.5 | 147.0 | 235 |
12 x 2 x 0.50 | 13.9 | 168.0 | 298 |
14 x 2 x 0.50 | 14.8 | 197.0 | 343 |
2 x 2 x 0.75 | 8.3 | 55.0 | 86 |
3 x 2 x 0.75 | 8.8 | 70.0 | 109 |
4 x 2 x 0.75 | 9.8 | 90.0 | 137 |
5 x 2 x 0.75 | 10.5 | 106.0 | 163 |
6 x 2 x 0.75 | 11.5 | 136.0 | 190 |
8 x 2 x 0.75 | 13.1 | 167.0 | 245 |
10 x 2 x 0.75 | 15.1 | 208.0 | 310 |
12 x 2 x 0.75 | 16.1 | 239.0 | 402 |
14 x 2 x 0.75 | 17.2 | 271.0 | 453 |
2 x 2 x 1.00 | 9,2 | 50.0 | 100 |
3 x 2 x 1.00 | 9.5 | 85.0 | 130 |
4 x 2 x 1.00 | 10.5 | 116.0 | 160 |
5 x 2 x 1.00 | 11.2 | 144.0 | 190 |
6 x 2 x 1.00 | 12.5 | 166.0 | 230 |
8 x 2 x 1.00 | 14.1 | 207.0 | 295 |
10 x 2 x 1.00 | 16.0 | 258.0 | 365 |
12 x 2 x 1.00 | 16.8 | 299.0 | 471 |
14 x 2 x 1.00 | 17.9 | 341.0 | 533 |
2 x 2 x 1.50 | 10.0 | 68.0 | 132 |
3 x 2 x 1.50 | 10.6 | 92.0 | 162 |
4 x 2 x 1.50 | 11.6 | 120.0 | 201 |
5 x 2 x 1.50 | 13.4 | 146.0 | 252 |
6 x 2 x 1.50 | 14.5 | 172.0 | 294 |
8 x 2 x 1.50 | 15.8 | 222.0 | 363 |
10 x 2 x 1.50 | 18.2 | 276.0 | 452 |
12 x 2 x 1.50 | 18.6 | 320.0 | 518 |
14 x 2 x 1.50 | 19.8 | 374.0 | 590 |
2 x 2 x 2.50 | 12.6 | 102.0 | 202 |
3 x 2 x 2.50 | 13.5 | 146.0 | 282 |
4 x 2 x 2.50 | 14.8 | 188.0 | 316 |
5 x 2 x 2.50 | 16.6 | 230.0 | 392 |
6 x 2 x 2.50 | 18.2 | 276.0 | 462 |
8 x 2 x 2.50 | 20.0 | 360.0 | 676 |
10 x 2 x 2.50 | 23.0 | 445.0 | 725 |
12 x 2 x 2.50 | 23.5 | 526.0 | 838 |
14 x 2 x 2.50 | 25.0 | 612.0 | 960 |
Categories: Fire Alarm Cables, PVC Signal Control Cables, Signal Control Cables