![](https://alturathgroup.com/wp-content/uploads/2019/12/LIYY-TP-540x220.png)
LIY(St)CY-TP
Application Area
These cables are used for connections in the electronic control technology, signal and data transmission cables for voice frequency transmissions.
Cable Construction
Inner Conductor |
Electrolytic Twisted Copper Wire, Class 5 IEC 60228; DIN VDE 0295 |
Insulation |
PVC, DIN 47100 Suitable for isolated color application EN 502902-2-21 TI52 |
Pairs |
Cores are stranded to pairs
|
Stranding |
Pairs twisted in layers |
Polyester |
Pet Band 100% Coverage |
Foil |
Al-Pet Foil 100% Coverage |
Screen |
Tinned Copper Braid Wire
|
Outer sheath |
PVC, RAL 7001 Grey EN 50290-2-22 TM52 |
Technicial Properties
Operating Temperature | -30°C … + 70°C |
Min. Bending radius | 15 x D |
Insulation Resistance | 200 MΩ x km |
Operating Voltage | |
0.22 mm² – 0.34 mm² | 250 V |
≥0.50 mm2 | 300/500 V |
Test Voltage | |
0.22 ve 0.34 mm² | 1200 V |
≥0.50 mm² | 2000 V |
Packing | 500 / 1000 m |
Standards
TSE K 353, DIN VDE 0812 |
Euro Class |
Eca |
Flame Retardancy Test |
EN 60332-1-2 |
EMC |
Electromagnetic compatibility |
Conductor Cross Section (mm²) |
Conductor Resistance max. (Ohm/km @ 20 °C) |
0.22 mm² | 96.00 Ω/km |
0.34 mm² | 56.00 Ω/km |
0.50 mm² | 39.00 Ω/km |
0.75 mm² | 26.00 Ω/km |
1.00 mm² | 19.50 Ω/km |
1.50 mm² | 13.30 Ω/km |
2.50 mm² | 7.98 Ω/km |
No. Of Cores x Cross Section (mm²) |
Overall Diameter (mm) |
Copper Weight (kg/km) |
Cable Approx. Weight (kg/km) |
2 x 2 x 0.22 | 6.0 | 21.0 | 45 |
3 x 2 x 0.22 | 6.4 | 22.0 | 60 |
4 x 2 x 0.22 | 6.8 | 29.0 | 68 |
5 x 2 x 0.22 | 7.5 | 34.0 | 80 |
6 x 2 x 0.22 | 8.2 | 38.0 | 94 |
8 x 2 x 0.22 | 9.0 | 48.0 | 112 |
10 x 2 x 0.22 | 10.4 | 58.0 | 142 |
12 x 2 x 0.22 | 10.6 | 64.0 | 155 |
14 x 2 x 0.22 | 11.4 | 74.0 | 175 |
2 x 2 x 0.34 | 6.4 | 28.0 | 56 |
3 x 2 x 0.34 | 6.7 | 39.0 | 67 |
4 x 2 x 0.34 | 7.5 | 55.0 | 84 |
5 x 2 x 0.34 | 8.2 | 63.0 | 97 |
6 x 2 x 0.34 | 8.8 | 74.0 | 114 |
8 x 2 x 0.34 | 9.9 | 88.0 | 144 |
10 x 2 x 0.34 | 11.2 | 116.0 | 169 |
12 x 2 x 0.34 | 13.2 | 131.0 | 253 |
14 x 2 x 0.34 | 14.1 | 146.0 | 282 |
2 x 2 x 0.50 | 7.7 | 36.0 | 76 |
3 x 2 x 0.50 | 8.2 | 50.0 | 92 |
4 x 2 x 0.50 | 8.9 | 70.0 | 112 |
5 x 2 x 0.50 | 9.9 | 81.0 | 136 |
6 x 2 x 0.50 | 10.6 | 96.0 | 157 |
8 x 2 x 0.50 | 12.1 | 116.0 | 201 |
10 x 2 x 0.50 | 13.6 | 152.0 | 239 |
12 x 2 x 0.50 | 13.9 | 173.0 | 303 |
14 x 2 x 0.50 | 14.8 | 202.0 | 347 |
2 x 2 x 0.75 | 8.4 | 59.0 | 93 |
3 x 2 x 0.75 | 8.9 | 78.0 | 114 |
4 x 2 x 0.75 | 9.9 | 97.0 | 142 |
5 x 2 x 0.75 | 10.7 | 113.0 | 167 |
6 x 2 x 0.75 | 11.6 | 143.0 | 194 |
8 x 2 x 0.75 | 13.2 | 174.0 | 250 |
10 x 2 x 0.75 | 15.2 | 215.0 | 316 |
12 x 2 x 0.75 | 16.1 | 246.0 | 409 |
14 x 2 x 0.75 | 17.2 | 279.0 | 460 |
2 x 2 x 1.00 | 8.9 | 71.0 | 104 |
3 x 2 x 1.00 | 9.6 | 95.0 | 135 |
4 x 2 x 1.00 | 10.5 | 125.0 | 165 |
5 x 2 x 1.00 | 11.3 | 154.0 | 195 |
6 x 2 x 1.00 | 12.6 | 175.0 | 236 |
8 x 2 x 1.00 | 14.2 | 216.0 | 300 |
10 x 2 x 1.00 | 16.1 | 268.0 | 371 |
12 x 2 x 1.00 | 16.8 | 309.0 | 481 |
14 x 2 x 1.00 | 17.9 | 351.0 | 542 |
2 x 2 x 1.50 | 10.5 | 66.0 | 138 |
3 x 2 x 1.50 | 11.2 | 92.0 | 172 |
4 x 2 x 1.50 | 12.2 | 118.0 | 216 |
5 x 2 x 1.50 | 13.8 | 146.0 | 272 |
6 x 2 x 1.50 | 15.0 | 170.0 | 318 |
8 x 2 x 1.50 | 16.4 | 222.0 | 382 |
10 x 2 x 1.50 | 18.8 | 276.0 | 482 |
12 x 2 x 1.50 | 19.4 | 322.0 | 548 |
14 x 2 x 1.50 | 20.5 | 374.0 | 624 |
2 x 2 x 2.50 | 12.8 | 102.0 | 205 |
3 x 2 x 2.50 | 14.0 | 146.0 | 265 |
4 x 2 x 2.50 | 15.4 | 187.0 | 330 |
5 x 2 x 2.50 | 17.0 | 230.0 | 404 |
6 x 2 x 2.50 | 18.8 | 276.0 | 494 |
8 x 2 x 2.50 | 20.6 | 360.0 | 610 |
10 x 2 x 2.50 | 22.6 | 444.0 | 755 |
12 x 2 x 2.50 | 24.2 | 526.0 | 875 |
14 x 2 x 2.50 | 26.2 | 612.0 | 1020 |
Categories: Fire Alarm Cables, PVC Signal Control Cables, Signal Control Cables