LIY(St)Y-TP
Application Area
These cables are used for connections in the electronic control technology, signal and data transmission cables for voice frequency transmissions.
Cable Construction
Inner Conductor |
Electrolytic Twisted Copper Wire, Class 5 IEC 60228; DIN VDE 0295 |
Insulation |
PVC, DIN 47100 Suitable for isolated color application EN 502902-2-21 TI52 |
Pairs |
Cores are stranded to pairs
|
Stranding |
Twisted in group
|
Polyester |
Pet Band 100% Coverage |
Drain Wire |
Tinned Copper Drain Wire
|
Foil |
Al-Pet Foil 100% Coverage |
Outer sheath |
PVC, RAL 7001 Grey EN 50290-2-22 TM52 |
Technicial Properties
Operating Temperature | -30°C … + 70°C |
Min. Bending radius | 15 x D |
Insulation Resistance | 200 MΩ x km |
Operating Voltage | |
0.22 mm² – 0.34 mm² | 250V |
≥0.50 mm2 | 300/500 V |
Test Voltage | |
0.22 ve 0.34 mm² | 1200 V |
≥0.50 mm² | 2000 V |
Packing | 500 / 1000 m |
Standards
TSE K 353, DIN VDE 0812 |
Euro Class |
Eca |
Flame Retardancy Test |
EN 60332-1-2 |
EMC |
Electromagnetic compatibility |
Conductor Cross Section (mm²) |
Conductor Resistance max. (Ohm/km @ 20 °C) |
0.22 mm² | 96.00 Ω/km |
0.34 mm² | 56.00 Ω/km |
0.50 mm² | 39.00 Ω/km |
0.75 mm² | 26.00 Ω/km |
1.00 mm² | 19.50 Ω/km |
1.50 mm² | 13.30 Ω/km |
2.50 mm² | 7.98 Ω/km |
No. Of Cores x Cross Section (mm²) |
Overall Diameter (mm) |
Copper Weight (kg/km) |
Cable Approx. Weight (kg/km) |
2 x 2 x 0.22 | 5.6 | 12.0 | 34 |
3 x 2 x 0.22 | 6.0 | 16.0 | 43 |
4 x 2 x 0.22 | 6.5 | 20.0 | 61 |
5 x 2 x 0.22 | 7.2 | 24.0 | 70 |
6 x 2 x 0.22 | 7.8 | 30.0 | 80 |
8 x 2 x 0.22 | 8.6 | 38.0 | 108 |
10 x 2 x 0.22 | 10.0 | 45.0 | 128 |
12 x 2 x 0.22 | 10.2 | 54.0 | 142 |
14 x 2 x 0.22 | 10.8 | 62.0 | 162 |
2 x 2 x 0.34 | 5.7 | 16.0 | 40 |
3 x 2 x 0.34 | 6.0 | 23.0 | 50 |
4 x 2 x 0.34 | 6.8 | 29.0 | 64 |
5 x 2 x 0.34 | 7.5 | 35.0 | 77 |
6 x 2 x 0.34 | 8.1 | 42.0 | 90 |
8 x 2 x 0.34 | 9.2 | 55.0 | 117 |
10 x 2 x 0.34 | 10.7 | 68.0 | 145 |
12 x 2 x 0.34 | 12.2 | 81.0 | 173 |
14 x 2 x 0.34 | 13.3 | 93.0 | 204 |
2 x 2 x 0.50 | 6.8 | 24.0 | 53 |
3 x 2 x 0.50 | 7.5 | 34.0 | 72 |
4 x 2 x 0.50 | 8.2 | 43.0 | 88 |
5 x 2 x 0.50 | 9.2 | 53.0 | 110 |
6 x 2 x 0.50 | 9.9 | 63.0 | 130 |
8 x 2 x 0.50 | 11.4 | 82.0 | 168 |
10 x 2 x 0.50 | 12.9 | 101.0 | 202 |
12 x 2 x 0.50 | 13.1 | 121.0 | 226 |
14 x 2 x 0.50 | 14.0 | 140.0 | 258 |
2 x 2 x 0.75 | 7.7 | 36.0 | 70 |
3 x 2 x 0.75 | 8.2 | 51.0 | 90 |
4 x 2 x 0.75 | 9.2 | 65.0 | 116 |
5 x 2 x 0.75 | 10.0 | 80.0 | 140 |
6 x 2 x 0.75 | 11.1 | 94.0 | 169 |
8 x 2 x 0.75 | 12.5 | 123.0 | 213 |
10 x 2 x 0.75 | 14.4 | 152.0 | 266 |
12 x 2 x 0.75 | 15.3 | 181.0 | 314 |
14 x 2 x 0.75 | 16.4 | 210.0 | 360 |
2 x 2 x 1.00 | 8.2 | 48.0 | 80 |
3 x 2 x 1.00 | 8.7 | 68.0 | 106 |
4 x 2 x 1.00 | 9.8 | 87.0 | 137 |
5 x 2 x 1.00 | 10.8 | 106.0 | 170 |
6 x 2 x 1.00 | 11.9 | 125.0 | 201 |
8 x 2 x 1.00 | 13.5 | 164.0 | 261 |
10 x 2 x 1.00 | 15.5 | 203.0 | 325 |
12 x 2 x 1.00 | 16.0 | 241.0 | 382 |
14 x 2 x 1.00 | 17.1 | 280.0 | 438 |
2 x 2 x 1.50 | 10.0 | 58.0 | 124 |
3 x 2 x 1.50 | 10.8 | 82.0 | 162 |
4 x 2 x 1.50 | 11.8 | 108.0 | 202 |
5 x 2 x 1.50 | 13.5 | 132.0 | 252 |
6 x 2 x 1.50 | 14.6 | 158.0 | 306 |
8 x 2 x 1.50 | 16.0 | 202.0 | 362 |
10 x 2 x 1.50 | 18.5 | 251.0 | 455 |
12 x 2 x 1.50 | 18.8 | 307.0 | 524 |
14 x 2 x 1.50 | 20.0 | 350.0 | 602 |
2 x 2 x 2.50 | 12.5 | 94.0 | 176 |
3 x 2 x 2.50 | 13.5 | 132.0 | 258 |
4 x 2 x 2.50 | 15.0 | 172.0 | 315 |
5 x 2 x 2.50 | 16.5 | 211.0 | 384 |
6 x 2 x 2.50 | 18.5 | 252.0 | 462 |
8 x 2 x 2.50 | 20.2 | 334.0 | 582 |
10 x 2 x 2.50 | 23.2 | 414.0 | 732 |
12 x 2 x 2.50 | 23.8 | 496.0 | 842 |
14 x 2 x 2.50 | 25.8 | 580 | 988 |
Categories: Fire Alarm Cables, PVC Signal Control Cables, Signal Control Cables